BIL is an abbreviation for Basic Insulation Level. Insulation levels in electrical equipment are characterized by the withstand voltages used during the impulse test. BIL rating specifies the minimum voltage that transformer can withstand under this condition.

What is Bil value?

The basic insulation level or BIL of an electrical equipment determines the principle dielectric qualities of the apparatus and is expressed for impulse tested apparatus by peak value of the 1/50 microsecond full wave withstand voltage.

How is BIL rating calculated?

The minimum level is known as the Basic Insulation Level (BIL) that must be that of all of the components of a system….Basic insulation level, kV. (standard 1.5- × 40-μs wave)

Basic insulation level, kV (standard 1.5- × 40-μs wave)
1.2 30 45
2.5 45 60
5.0 60 75
8.7 75 95

What is bil in electrical engineering?

High level. source: http://acronyms.thefreedictionary.com/HL.

What is rated insulation level?

The rated insulation level is the value of the impulse withstand voltage and the value of the power frequency withstand voltage, which together characterise the insulation of the switchgear with regard to its ability to withstand the electric stresses.

What is rated insulation voltage?

Rated insulation voltage (Ui) “The rated insulation voltage of an equipment is the value of voltage to which dielectric tests and creepage distances are referred. In no case shall the maximum value of the rated operational voltage exceed that of the rated insulation voltage”.

What is the full form of Bil?

BIL. Brother-In-Law. BIL.

What is Bil basic impulse level?

Basic impulse level is a means to express the ability of the insulation system to withstand high voltage surges.

What is insulation level of current transformer?

Rated insulation level means the Power frequency and Impulse voltage withstand test voltages specified for the CT.

What is ICU and ICW?

Icu is nothing but unlimited break Capacity of the circuit breaker Which means the circuit breaker can break the maximum fault current without damage.

What is UI and uimp?

Ui is the voltage that references the voltage environment. The rated impulse withstand voltage Uimp sets the maximum voltage a circuit breaker can withstand without failure. It is expressed in kilovolts (kV). In an apartment, for example, 4kV is ample, while industrial devices have Uimp of up to 8 kV.

What is bil and how does it apply to Transformers?

The BIL of a transformer is a method used to specify the magnitude of the voltage surge that a transformer can tolerate without any damage to the windings and live parts of the transformer. When lightning impulse over voltage appears in the system, it is discharged through surge protecting device before the transformer gets damaged.

What does Bil stand for in electrical insulation?

BIL stands for basic lightning impulse insulation level although this is often shortened to basic impulse level or basic insulation level. BIL is not the same as the withstand strength of an insulation system.

What’s the Bil rating for a TX Transformer?

The BIL on the Tx you have purchased is in line with standard BIL rating specified for that voltage (ie 13.8kV)as per IEC (and perhaps ANSI as well). You should stay calm and ask formally the utility to explain their technical objection to the BIL of 95kV.

How is the Bil of an electrical apparatus determined?

The basic insulation level or BIL of an electrical equipment determines the principle dielectric qualities of the apparatus and is expressed for impulse tested apparatus by peak value of the 1/50 microsecond full wave withstand voltage.