A Kelvin bridge, also called a Kelvin double bridge and in some countries a Thomson bridge, is a measuring instrument used to measure unknown electrical resistors below 1 ohm. It is specifically designed to measure resistors that are constructed as four terminal resistors.

Why kelvin double bridge is called Double bridge method?

The kelvin double bridge incorporates the idea of a second set of ratio arms – hence the name double bridge- and the use of four terminal resistors for the low resistance arms. The ratio p/q is made equal to P/Q.

What is the essential condition for Kelvins Double bridge?

For obtaining the appropriate result, it is very essentials that the ratio of their arms is equal. The unequal arm ratio causes the error in the result. Also, the value of resistance r should be kept minimum for obtaining the exact result. The thermo-electric EMF induces in the bridge during the reading.

What is the reason for which Kelvin bridge is used for measurement of low resistance?

17. Why Kelvin bridge is used for measurement of low resistance? Explanation: While measuring very low resistances the contact and lead resistances cause significant errors in the value of the measured resistance. As a result Kelvin bridge is used for measurement of low resistances.

What is the use of kelvins method?

Hint:Kelvin’s method determines the resistance of the galvanometer using the principle of Wheatstone bridge, which makes it easier to find the resistance since you only need to know the ratio of the lengths and not the specific value of resistance of wires.

What is balance point in kelvins method?

Explanation: The balance point in the kelvin resistance measurement is the actual galvanometer coil resistance / impedance as represented by the voltage drop across the coil divided by the current coming out of the test probes & passing through the galvanometer coil itself .

What are the advantages of Kelvin double bridge over potentiometer?

Because by using Kelvin’s Double Bridge, your end result i.e. the value of unknown resistance will not be influenced by resistances of connecting lead.

Why is the Kelvin Double bridge more accurate?

In order to avoid this problem, Kelvin’s double bridge is used. It is so constructed that the contact resistance will not come into the picture while measuring the value of low resistance. Hence, Kelvin’s double bridge greatly improves the accuracy of measurement by eliminating the effect of contact resistance.

Why kelvins method is called as equal deflection method?

Explanation: Only then will there be a point D on the wire which is equipotential with point B. The jockey is tapped along the wire to locate the equipotential point D when the galvanometer shows no change in deflection. Here, point D is called the balance point and Kelvin’s method is thus an equal deflection method.

What is Kelvin method?

Why Kelvin method is called as equal deflection method?

What is the accuracy of Kelvin double bridge?

What is the accuracy of Kelvin Double Bridge? The unknown resistance value can be obtained from the two arms of Kelvin double bridge, typically, it measures 1- 0.00001 ohm with an accuracy ± 0.05% to ±0.2%. A bridge is an electrical circuit, which is used in Labourites for measuring various parameters.

What is the purpose of the Kelvin bridge?

Kelvin Bridge. Definition: The Kelvin bridge or Thompson bridge is used for measuring the unknown resistances having a value less than 1Ω. It is the modified form of the Wheatstone Bridge. Wheatstone bridge use for measuring the resistance from a few ohms to several kilo-ohms.

Is the Kelvin bridge independent of load and contact resistance?

There is no effect of load and contact resistance in the Kelvin bridge since the bridge is independent of load and contact resistance. 7). What is the accuracy of Kelvin Double Bridge? The unknown resistance value can be obtained from the two arms of Kelvin double bridge, typically, it measures 1- 0.00001 ohm with an accuracy ± 0.05% to ±0.2%.

Why is the Wheatstone bridge used instead of the Kelvin bridge?

Wheatstone bridge use for measuring the resistance from a few ohms to several kilo-ohms. But error occurs in the result when it is used for measuring the low resistance. This is the reason because of which the Wheatstone bridge is modified, and the Kelvin bridge obtains.