Table of Contents
How much oil is in a 1000 KVA transformer?
1-2. 33kV – 400/230V
Item | Capacity | Oil |
---|---|---|
kVA | Liter | |
8 | 630 | 550 |
9 | 800 | 700 |
10 | 1,000 | 750 |
Which oil is used in transformer insulation?
Naphthenic mineral oil
Naphthenic mineral oil has long been the most preferred insulating liquid for power transformer insulation because it has a good pouring point at low temperatures, good thermal cooling capacity, low cost, high efficiency and availability on the transformers market [1, 2, 3, 7].
What is 750 kva transformer?
3-Phase 750 kVA Distribution Transformer
Number of Phase | 3-Phase |
---|---|
Voltage Ratio | 11kV/433V |
Cooling Type | Oil Cooled |
Winding Material | Aluminium |
Power | 750 KVA |
What is OTI and WTI in transformer?
The WTI means winding temperature Indicator and OTI means Oil Temperature Indicator which indicates the winding temperature & oil temperature of the transformer and operates the alarm, trip, and cooler control contacts.
How much oil does a 25 kVA transformer take?
Product Specification
Voltage rating | 11/.433KV |
---|---|
Insulating Fluid | Mineral Oil |
Tank Capacity | 145 L |
Weight | 400 Kg |
Condition | Fresh |
How do you test insulation resistance on a transformer?
IR Value Measurement (Conductor to Earth Insulation)
- Connect conductor under test to the Line terminal of the megger.
- Connect earth terminal of the megger to the earth.
- Rotate the handle of megger or press push button of megger. The reading of meter will show the insulation resistance of the conductors.
How many amps can a 750 kva transformer handle?
Three Phase Transformers, Full Load Amperes (FLC) | ||
---|---|---|
KVA | 208V | 480V |
500 | 1387 | 601 |
750 | 2084 | 903 |
1000 | 2779 | 1204 |
What is Rtcc panel?
RTCC stands for Remote Tap Changer Control. RTCC panel used to control the transformer output voltage by controlling the OLTC unit of the transformer. OLTC controls the winding tap position of the Transformer and it resulted in the output voltage also changes.
What are the specs for a 500 kVA transformer?
TECHNICAL SPECIFICATION FOR OUTDOOR 3 PHASE 500 KVA AMORPHOUS / CRGO CORE CSP TYPE COPPER WOUND DISTRIBUTION TRANSFORMERS 1. SCOPE : This standard covers oil immersed naturally cooled, three phase, 50Hz, CSP type double wound outdoor type Distribution Transformer of 500 KVA for use on systems with nominal voltages of 11KV.
What are the specs for dry type transformers?
DRY-TYPE (VPI) DISTRIBUTION TRANSFORMERS (Indoor and Outdoor). Tech Spec. No. CE/T-QC/MSC/Dry Type Dist Transformer dtd.08.10.2020 Page 7 6.4 Coreclamping: a. M.S channel 125 mm x 65 mm for 100 &200 kVA, 150 x 75 mm for 315 & 630 kVA transformer and 200 X 75 mm for 1000 kVA ,1250 KVA , 1600 Kva,2000 KVA &2500 KVA transformers on Top and Bottom.
What is the physical basis of a transformer?
The physical basis of a transformer is mutual induction between two circuits linked by a common magnetic flux. In its simplest form, it consists of two inductive coils which are electrically separated but magnetically linked through a path of low reluctance as shown in Fig. 32.1.